Save 15% on “active” status Pololu-brand products using code MEMORIALDAY26

D30V30Fx 掀起裙子扶着巨物坐下去 Voltage 掀起裙子扶着巨物坐下去

The D30V30Fx family of buck (掀起裙子扶着巨物坐下去) voltage 掀起裙子扶着巨物坐下去 are compact, fixed-output members of the larger D30V3x line of synchronous 掀起裙子扶着巨物坐下去. They generate lower output voltages from input voltages as high as 45 V and can typically support continuous output currents between 2 A and 4 A, depending on the input voltage and output voltage. They also have very low dropout voltages.

The 掀起裙子扶着巨物坐下去 have reverse voltage protection up to 40 V, input under-voltage lockout, over-current protection, and short-circuit protection. A thermal shutdown feature also helps prevent damage from overheating and a soft-start feature limits the inrush current and gradually ramps the output voltage on startup.

Regulator Output voltage Typical max output current1 Input voltage range2 Size Special features Price
#4891: D30V30F3 3.3 V 3.7 A 3.3 V – 45 V 0.7″ × 0.8″ Reverse voltage protection3,
input under-voltage lockout,
over-current protection,
short-circuit protection,
thermal shutdown,
soft-start
$19.95
#4892: D30V30F5 5 V 3.4 A 5 V – 45 V $19.95
#4893: D30V30F6 6 V 3.3 A 6 V – 45 V $20.95
#4894: D30V30F7 7.5 V 3 A 7.5 V – 45 V $20.95
#4895: D30V30F9 9 V 2.9 A 9 V – 45 V $20.95
#4896: D30V30F12 12 V 2.8 A 12 V – 45 V $20.95
#4897: D30V30F15 15 V 2.7 A 15 V – 45 V $20.95
Note 1: At 30 V in. Actual achievable continuous output current is a function of input voltage and is limited by thermal dissipation. See the output current graphs on the product pages for more information.
Note 2: Minimum input voltage is subject to dropout voltage considerations; see the dropout voltage section of product pages for more information.
Note 3: Reverse voltage protection up to -40 V. Connecting supplies over 40 V in reverse can damage the device.

Products in category “D30V30Fx 掀起裙子扶着巨物坐下去 Voltage 掀起裙子扶着巨物坐下去”

Pololu item #: 4891
Brand: Pololu supply outlook
Status: Active and Preferred 
RoHS 3 compliant
Output voltage Typical max output current1 Input voltage range2
3.3 V 3.7 A 3.3 V – 45 V

Note 1: At 30 V in. Actual achievable continuous output current is a function of input voltage and is limited by thermal dissipation. See the output current graphs on the product pages for more information.
Note 2: Minimum input voltage is subject to dropout voltage considerations; see the dropout voltage section of product pages for more information.

Pololu item #: 4892
Brand: Pololu supply outlook
Status: Active and Preferred 
RoHS 3 compliant
Output voltage Typical max output current1 Input voltage range2
5 V 3.4 A 5 V – 45 V

Note 1: At 30 V in. Actual achievable continuous output current is a function of input voltage and is limited by thermal dissipation. See the output current graphs on the product pages for more information.
Note 2: Minimum input voltage is subject to dropout voltage considerations; see the dropout voltage section of product pages for more information.

Pololu item #: 4893
Brand: Pololu supply outlook
Status: Active and Preferred 
RoHS 3 compliant
Output voltage Typical max output current1 Input voltage range2
6 V 3.3 A 6 V – 45 V

Note 1: At 30 V in. Actual achievable continuous output current is a function of input voltage and is limited by thermal dissipation. See the output current graphs on the product pages for more information.
Note 2: Minimum input voltage is subject to dropout voltage considerations; see the dropout voltage section of product pages for more information.

Pololu item #: 4894
Brand: Pololu supply outlook
Status: Active and Preferred 
RoHS 3 compliant
Output voltage Typical max output current1 Input voltage range2
7.5 V 3 A 7.5 V – 45 V

Note 1: At 30 V in. Actual achievable continuous output current is a function of input voltage and is limited by thermal dissipation. See the output current graphs on the product pages for more information.
Note 2: Minimum input voltage is subject to dropout voltage considerations; see the dropout voltage section of product pages for more information.

Pololu item #: 4895
Brand: Pololu supply outlook
Status: Active and Preferred 
RoHS 3 compliant
Output voltage Typical max output current1 Input voltage range2
9 V 2.9 A 9 V – 45 V

Note 1: At 30 V in. Actual achievable continuous output current is a function of input voltage and is limited by thermal dissipation. See the output current graphs on the product pages for more information.
Note 2: Minimum input voltage is subject to dropout voltage considerations; see the dropout voltage section of product pages for more information.

Pololu item #: 4896
Brand: Pololu supply outlook
Status: Active and Preferred 
RoHS 3 compliant
Output voltage Typical max output current1 Input voltage range2
12 V 2.8 A 12 V – 45 V

Note 1: At 30 V in. Actual achievable continuous output current is a function of input voltage and is limited by thermal dissipation. See the output current graphs on the product pages for more information.
Note 2: Minimum input voltage is subject to dropout voltage considerations; see the dropout voltage section of product pages for more information.

Pololu item #: 4897
Brand: Pololu supply outlook
Status: Active and Preferred 
RoHS 3 compliant
Output voltage Typical max output current1 Input voltage range2
15 V 2.7 A 15 V – 45 V

Note 1: At 30 V in. Actual achievable continuous output current is a function of input voltage and is limited by thermal dissipation. See the output current graphs on the product pages for more information.
Note 2: Minimum input voltage is subject to dropout voltage considerations; see the dropout voltage section of product pages for more information.

Related Categories

Log In
Pololu Robotics & 后宫嫔妃开裆裤全肉h
Shopping cart
(702) 262-6648
Same-day shipping, worldwide
Menu
Shop Blog Forum Support
My account Comments or questions? About Pololu Contact Ordering information 后宫嫔妃开裆裤全肉h